SPS-NH3 Capteur d'ammoniac et d'azote pour l'eau

Ammonia nitrogen is a common pollutant in industrial, agricultural, and domestic sewage. Ammonium nitrogen depletes dissolved oxygen in water bodies and leads to eutrophication. Ammonium ions are measured using the ion-selective method, which consists of a working electrode, a reference electrode, an ion-selective membrane, and an electrolyte. Only the ammonium ions to be measured can pass through the ion-selective membrane and undergo a charge change, generating a potential at the working electrode proportional to the ion concentration and a constant potential at the reference electrode. The controller is based on the Nernst equation, which measures the potential difference between the working and reference electrodes and converts it to the ammonia nitrogen concentration based on the potentiometric measurement principle, independent of coloration and turbidity.
It is suitable for online and portable monitoring of municipal sewage, domestic sewage, agricultural sewage, industrial sewage, process control, nitrification treatment, aeration tanks, etc. It is suitable for integrated applications such as buoy, floating discharge, and vessel monitoring.

Parameter: NH3-N, NH4+, Temperature

  • Quick measurement: the shortest measurement cycle is 1 second
  • RS485 communication mode can quickly connect the meter controller, control the sensor
  • IP68 protection grade can be used in harsh environments
  • Low power consumption, can be powered by battery, convenient for equipment deployment

Spécifications

ObjetSpécifications
PrincipeIon-selective electrode method potentiostatic 3-electrode
Dimensionφ25×226mm
Exigences en matière d'alimentationDC+12V~+24V
Température de fonctionnement2 à 50℃
Pression1 bar
InstallationSubmergée, à écoulement continu
Débit de l'échantillon200-500mL/min
CommunicationRS485(Modbus RTU), Bluetooth

Paramètres

ParamètresNuméro de modèleGammeRésolutionPrécision
(Standard solution)
NH3-NSPS-NH30-100 mg/L, 0-1000 mg/L, 0-2000 mg/L0.001 mg/L ±3% F.S.
TempératureSPS-NH32-50 °C 0.1 °C ±1 °C

SPS-NH3 Datasheet

Brochure Specsens

Application

Sewage Treatment plant water sensor analying
Rural Sewage Treatment Station

The central control system timely controls the time required for each reaction stage through data fed back by sensors, greatly improving the efficiency of sewage treatment facilities.