{"id":4265,"date":"2026-02-11T20:19:59","date_gmt":"2026-02-11T12:19:59","guid":{"rendered":"https:\/\/www.specsens.com\/?p=4265"},"modified":"2026-02-11T20:20:54","modified_gmt":"2026-02-11T12:20:54","slug":"turbidity-tss-sensor-installation","status":"publish","type":"post","link":"https:\/\/www.specsens.com\/ru\/turbidity-tss-sensor-installation\/","title":{"rendered":"Installation of SPS-T-SC1 Turbidity\/Suspended Matter Sludge Concentration Sensor"},"content":{"rendered":"<p class=\"has-text-align-left\">The SPS-T-SC1 turbidity\/suspended solids (sludge concentration) sensor is a<br>turbidity and suspended solids sensor based on the 90\u00b0 and backscattered light<br>measurement principle. Mainly used in the fields of surface water, domestic<br>sewage and industrial sewage. The turbidity sensor is equipped with automatic<br>optical window cleaning function. In addition, with the MC-W-S series controller<br>and SPS-Server (SPS cloud service), users can realize on-site and remote data<br>viewing.<\/p>\n\n\n\n<p class=\"has-text-align-left\">The SPS-T-SC1 sensor adopts the principle of scattered light measurement.<br>The 860nm laser light source emits light, the 90\u00b0 detector receives the light<br>scattered by the suspended matter in the water and generates a signal, and the<br>detectors at other point angles receive signals from other angles. According to<br>the proportional relationship between the two angle signal values and the<br>concentration of suspended solids in the water body, the turbidity and<br>suspended solids concentration of the water body can be calculated.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Installation of SPS-T-SC1<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Submerged installation<\/h3>\n\n\n\n<p>The sensor is mounted with a bracket.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"908\" height=\"1024\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Submerged-installation-908x1024.webp\" alt=\"Submerged installation\" class=\"wp-image-4271\" style=\"width:361px;height:auto\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Submerged-installation-908x1024.webp 908w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Submerged-installation-266x300.webp 266w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Submerged-installation-768x866.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Submerged-installation-11x12.webp 11w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Submerged-installation-600x676.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Submerged-installation.webp 1054w\" sizes=\"(max-width: 908px) 100vw, 908px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Pipe installation<\/h3>\n\n\n\n<p>This method of mounting the sensor is recommended for main pipe sizes<br>larger than 150 mm.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"853\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Pipe-holder-mounting-dimensions-1024x853.webp\" alt=\"Pipe holder mounting dimensions\" class=\"wp-image-4269\" style=\"width:369px;height:auto\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Pipe-holder-mounting-dimensions-1024x853.webp 1024w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Pipe-holder-mounting-dimensions-300x250.webp 300w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Pipe-holder-mounting-dimensions-768x640.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Pipe-holder-mounting-dimensions-14x12.webp 14w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Pipe-holder-mounting-dimensions-600x500.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Pipe-holder-mounting-dimensions.webp 1342w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"518\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Installation-methods-1024x518.webp\" alt=\"Installation methods\" class=\"wp-image-4268\" style=\"width:565px;height:auto\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Installation-methods-1024x518.webp 1024w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Installation-methods-300x152.webp 300w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Installation-methods-768x388.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Installation-methods-18x9.webp 18w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Installation-methods-600x303.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Installation-methods.webp 1384w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Flow-through installation<\/h3>\n\n\n\n<p>The flow cell is symmetrical, so please install it vertically and make sure that the water<br>flows in from the bottom and out from the top to ensure that the water flow fills the flow<br>cell.<br>Thread the limiter, locking ring, and union nut through the end of the sensor in sequence<br>as shown in the figure.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"876\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Flow-through-installation-structure-1024x876.webp\" alt=\"Flow-through installation structure\" class=\"wp-image-4266\" style=\"width:394px;height:auto\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Flow-through-installation-structure-1024x876.webp 1024w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Flow-through-installation-structure-300x257.webp 300w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Flow-through-installation-structure-768x657.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Flow-through-installation-structure-14x12.webp 14w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Flow-through-installation-structure-600x513.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Flow-through-installation-structure.webp 1410w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"586\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation-1024x586.webp\" alt=\"flow-through Vertical installation\" class=\"wp-image-4267\" style=\"width:543px;height:auto\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation-1024x586.webp 1024w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation-300x172.webp 300w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation-768x439.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation-1536x878.webp 1536w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation-18x10.webp 18w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation-600x343.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/flow-through-Vertical-installation.webp 1808w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"829\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/SC1-flow-through-installation-1024x829.webp\" alt=\"SC1 flow-through installation\" class=\"wp-image-4272\" style=\"width:334px;height:auto\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/SC1-flow-through-installation-1024x829.webp 1024w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/SC1-flow-through-installation-300x243.webp 300w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/SC1-flow-through-installation-768x622.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/SC1-flow-through-installation-15x12.webp 15w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/SC1-flow-through-installation-600x486.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/SC1-flow-through-installation.webp 1114w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Shield unit install<\/h3>\n\n\n\n<p>When installing the sensor in a bright light environment, such as outdoors, it is<br>necessary to install a shield unit to block the effects of bright light on the sensor<br>measurement.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"253\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Shield-unit-install-1024x253.webp\" alt=\"Shield unit install\" class=\"wp-image-4270\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Shield-unit-install-1024x253.webp 1024w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Shield-unit-install-300x74.webp 300w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Shield-unit-install-768x190.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Shield-unit-install-18x4.webp 18w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Shield-unit-install-600x148.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2026\/02\/Shield-unit-install.webp 1386w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/www.specsens.com\/ru\/product\/sps-t-sc1-turbidity-suspended-solids-water-quality-sensor\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor.webp\" alt=\"SPS-T-SC1 water quality sensor\" class=\"wp-image-3752\" style=\"width:357px;height:auto\" srcset=\"https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor.webp 1000w, https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor-300x300.webp 300w, https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor-150x150.webp 150w, https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor-768x768.webp 768w, https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor-12x12.webp 12w, https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor-600x600.webp 600w, https:\/\/www.specsens.com\/wp-content\/uploads\/2025\/04\/SPS-T-SC1-water-quality-sensor-100x100.webp 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/a><\/figure>\n\n\n\n<p><a href=\"https:\/\/www.specsens.com\/ru\/product\/sps-t-sc1-turbidity-suspended-solids-water-quality-sensor\/\">SPS-T-SC1 Turbidity\/Suspended Matter (Sludge Concentration) Sensor<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>The SPS-T-SC1 turbidity\/suspended solids (sludge concentration) sensor is aturbidity and suspended solids sensor based on the 90\u00b0 and backscattered lightmeasurement principle. Mainly used in the fields of surface water, domesticsewage and industrial sewage. The turbidity sensor is equipped with automaticoptical window cleaning function. In addition, with the MC-W-S series controllerand SPS-Server (SPS cloud service), users [&hellip;]<\/p>","protected":false},"author":1,"featured_media":4273,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[208],"tags":[],"class_list":["post-4265","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products-information"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/posts\/4265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/comments?post=4265"}],"version-history":[{"count":1,"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/posts\/4265\/revisions"}],"predecessor-version":[{"id":4274,"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/posts\/4265\/revisions\/4274"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/media\/4273"}],"wp:attachment":[{"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/media?parent=4265"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/categories?post=4265"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.specsens.com\/ru\/wp-json\/wp\/v2\/tags?post=4265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}