- Pass CE/RoHS/vibration/high and low-temperature test
- 1-3 months secondary water supply sensor maintenance-free
- 3 months factory water sensor maintenance-free
- Withstand pressure up to 1 MPa (10 atm)
- Highly integrated, can measure turbidity, organic matter
Specification
| Item | Specification |
|---|---|
| Principle | 90° scattering + UV spectrometry |
| Dimension | 150 × 82 × 175mm |
| Power requirements | DC+12V~+24V |
| Measurement period | 10 seconds to 65535 seconds |
| Operating temperature | 0 to 50℃ |
| Pressure | 10bar |
| Power | < 6W |
| Cleaning method | Cleaning brush |
| Sample flow rate | 200-500m L/min |
| Communication | RS485(Modbus RTU) |
Parameter
| Parameter | Model No. | Range | Resolution | Accuracy (Standard solution) |
|---|---|---|---|---|
| Turbidity | SPS-M-SC2 | 0-100 NTU | 0.001 NTU | ±2% or ±0.015 NTU |
| SPS-M-SC3 | ||||
| SPS-M-SC5 | ||||
| TOC | SPS-M-SC2 | 0-20 mg/L | 0.001 mg/L | ±2% F.S. |
| SPS-M-SC5 | ||||
| COD | SPS-M-SC3 | 0-50 mg/L | 0.001 mg/L | ±2% F.S. |
| SPS-M-SC5 |